1. It is not only used in freon-based refrigerants, but also for air and liquids: (allow liquid temperature: -10~+120°C);
2. Multi-point contact conversion function;
3. Using "single pole double throw" contact mechanical structure design;
4. Novel micro-switch structure, to ensure the reliable operation function;
5. Manual control, no need for any tool to carry out electrical contact function test;
6. Smart installation board, can be applied to different installation occasions.
Single Pressure Control can not be directly connected with industrial equipment when used, because the pressure controller itself can not complete the conversion, measurement, transmission and a series of these tasks. Attention should be paid to the following points when installing additional accessories, such as firmness, stability and so on. The following is a list of precautions for installation. You can refer to it.
The Single Pressure Control should add additional accessories in the following situations:
It is necessary to ensure that the pressure controller is not affected by the sharp change or the fluctuation pressure of the measured medium, and install a buffer. Especially when the pressure increases sharply and the pressure drops sharply, the pressure controller is most likely to be damaged and scrapped, and even the spring tube cracks and a leak will occur.
It is necessary to ensure that the Single Pressure Control is not affected by the high temperature of the measured medium, and the bending device filled with liquid should be installed.
Single Pressure Control is necessary to ensure that the Single Pressure Control is not affected by the crystallization of the measured medium, or that the corrosion or viscosity is too large to be used, so the isolation device should be installed.
It is necessary to ensure that the pressure controller is not affected by vibration. The Single Pressure Control should be equipped with shock absorber and fixing device.
Special grade pressure controller for other use shall be prohibited, and it is forbidden to measure on the special and reliable devices. It is also forbidden to use ordinary pressure gauges for pressure measurement of special medium.
For the newly purchased pressure controller, before installation and use, the metrological verification must be carried out to prevent the pressure controller from destroying accuracy by vibrating, damage or other factors during transportation.
Max. Operating Pressure (MPa): 4.0
Adjusting Range (MPa): -50cm Hg~3.0
allow liquid temperature: -10~+120°C
Technical Description of Single Pressure Control SNS Series:
1. It is not only used in freon-based refrigerants, but also for air and liquids: (allow liquid temperature: -10~+120°C);
2. Multi-point contact conversion function;
3. Using "single pole double throw" contact mechanical structure design;
4. Novel micro-switch structure, to ensure the reliable operation function;
5. Manual control, no need for any tool to carry out electrical contact function test;
6. Smart installation board, can be applied to different installation occasions.
Model | SNS-103 | SNS-106 | SNS-110 | SNS-120 | SNS-130 | |
Adjusting range (MPa) | Min | -50cm Hg | -50cm Hg | -50cm Hg | -50cm Hg | -50cm Hg |
Max | 0.3 | 0.6 | 1.0 | 2.0 | 3.0 | |
Output pressure (MPa) | Min | 0.035 | 0.06 | 0.1 | 0.3 | 0.3 |
Max | 0.2 | 0.4 | 0.3 | 0.5 | 1.0 | |
Setting value (MPa) | OFF(ON) | 0.05 | 0.1 | 0.4 | 1.5 | 2.0 |
ON(OFF) | 0.15 | 0.3 | 0.6 | 1.2 | 1.5 | |
Max. Operating Pressure (MPa) | 1.1 | 1.65 | 1.65 | 4.0 | 4.0 |
SNS Single Pressure Control | Pneumatic Cylinder Actuator